H FT-DX1200 OPERATOR'S MANUAL Page 117

FTDX1200 Operating Manual Page 117

MENU MODE Cont'd

Previous Page    Index of Topics    Table of Contents    Index of Pages    Next Page

MENU ITEM DETAILS Cont'd

063 CW BK-IN
Function: Sets the CW "break-in" mode.
Available Values: SEMI or FULL
Default Setting: SEMI

SEMI: The transceiver will operate in the semi break-in mode. The delay (receiver recovery) time is set via the Menu item "064 CW BK-IN DELAY".

FULL: The transceiver will operate in the full break-in (QSK) mode.


064 CW BK-IN DELAY
Function: Adjusts teh Keying Delay (receiver recovery) time on the CW mode.
Available Values: 30 ~ 3000 msec (10 msec/step)
Default Setting: 200 msec


065 CW WAVE SHAPE
Function: Selects the CW carrier wave-form shape (rise/fall times).
Available Values: 1, 2, 4 or 6 msec
Default Setting: 4 msec


066 CW FREQ DISPLAY
Function: Selects the frequency Display Format for the CW mode.
Available Values: DIRECT FREQ or PITCH OFFSET
Default Setting: PITCH OFFSET

DIRECT FREQ Displays the receiver carrier frequency, without any offset added. When changing modes between SSB and CW, the frequency display remains constant.

PITCH OFFSET This frequency display reflects the added BFO offset.


067 PC KEYING
Function: Enables/Disables CW keying from the "DATA RTTY" terminal (pin 3) of the RTTY/DATA jack on the rear panel, while operating on the CW mode.
Available Values: OFF or On
Default Setting: OFF


068 QSK
Function: Selects the time delay between when the PTT is keyed and the carrier is transmitted during QSK operation when using the internal keyer.
Available Values: 15, 20, 25, or 30 msec
Default Setting: 15 msec


End of Menu Item Details
"Mode-CW Group"


MODE-DATA GROUP

069 DATA MODE
Function: Selects the operation mode of the data mode.
Available Values: PSK or OTHER
Default Setting: PSK


070 PSK TONE
Function: Selects the PSK tone frequency.
Available Values: 1000, 1500 or 2000 Hz
Default Setting: 1000 Hz


071 OTHER DSP (SSB)
Function: Sets the packet display frequency display offset.
Available Values: -3000 ~ 0 ~ +3000 Hz (10 Hz/step)
Default Setting: 0


072 OTHER SHIFT (SSB)
Function: Sets the carrier point during the SSB packet operation.
Available Values: -3000 ~ 0 ~ +3000 Hz (10 Hz/step)
Default Setting: 1000 Hz (typical center frequency for PSK31, etc.)


073 DATA LCUT FREQ
Function: Selects the cutoff frequency of the lower side of the RX audio filter in the DATA mode.
Available Values: OFF, 100 ~ 1000 Hz (50 Hz/step)
Default Setting: 300


074 DATA LCUT SLOPE
Function: Selects the filter slope of the lower side of the RX audio filter in the DATA mode.
Available Values: 6dB/oct or 18dB/oct
Default Setting: 18dB/oct


075 DATA HCUT FREQ
Function: Selects the cutoff frequency of the upper side of the RX audio filter in the DATA mode.
Available Values: OFF, 700 ~ 4000 Hz (50 Hz/step)
Default Setting: 3000 Hz


076 DATA HCUT SLOPE
Function: Selects the filter slope of the upper side of the RX audio filter in the DATA mode.
Available Values: 6dB/oct or 18dB/oct
Default Setting: 18dB/oct


Cont'd Next Page Menu Items Details
"Mode DATA Group"

Cont'd Next Page "Menu Mode"

Previous Page    Index of Topics    Table of Contents    Back to Top    Index of Pages    Next Page

FTDX1200 Operating Manual Page 117